In service mode, look for PRINT DARKNESS or ENERGY setting. Typical range: 80-120. Higher values increase contrast but reduce head life.
The Digi SM-320 integrates precise weight measurement with a robust thermal label printer. It operates on advanced digital signal processing to ensure legal-for-trade accuracy. Key Specifications: digi sm320 service manual
A: Partially. The weighing and printing principles are similar, but PCBs and calibration routines differ. Find the exact model manual. In service mode, look for PRINT DARKNESS or ENERGY setting
Locate the span switch (usually a physical microswitch or jumper hidden beneath a sealed calibration plate under the scale base). Flip or press the switch while powering on the scale. In service mode